Intial step is to make a backup of VC Domain configuration from VC Manager GUI and you will require Virtual Connect Support Utility downloaded and installed on any machine.
Please follow the below steps:
1. Run VCSU from Start > Programs>Hewlert-Packard>Virtual Connect Support Utility> Virtual Connect Support Utility – Interactive.
Please enter action (“help” for list): update
Please enter Onboard Administrator IP Address: 192.162.0.91
Please enter Onboard Administrator Username: Administrator
Please enter Onboard Administrator Password : ***********
Please enter firmware package location : c:\temp\vcfwall3.18.bin
Please enter Bay Number (Optional):
Please enter configuration backup password (Optional):
Do you want to force an update on modules? (Yes/No):
Do you want to specify VC-Enet module activiation order? (Yes/No)
Do you want to specify VC-FC module activation order? (Yes/No):
Do you want to specifiy the amount of time in minutes to wait between activating or rebooting VC-Enet modules? (Yes/No):
Do you want to specifiy the amount of time in minutes to wait between activating or rebooting VC-FC modules? (Yes/No)
Please enter the VCM Domain user credentials.
User Name : Administrator
Password : ***********
Gathering module and package information. [Step 3 of 3: 30 seconds]
HP advised to use different versions of VCSU for Ethernet and FC Virtual Connect modules, however, it is not possible with multi enclosure configuration.
Reset all VC modules one by one, making sure you can see the new version and you have all connectivity through this module back.